Skip to main content

Specialized - Ignitron ·IgnitronPowerSwitch

I035

Mercury-cathode ignitron for high-current switching in timing devices, welding controls, X-ray equipment, magnetizing circuits, and accelerator systems.

Directly heatedCold cathodeCommon cathodeDissimilarSpecialized
Sections
1
Base
-
Socket code
-
Base pins
-
Nominal heater
-

Description

Mercury-cathode ignitron used as a high-current switching element in timing devices, welding controls, X-ray equipment, magnetizing circuits and accelerator systems.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
-
Nominal heater voltage
-
Nominal heater current
-
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

IgnitronPowerSwitch

X-ray radiationInterelectrode capacitances

No fixed ratings are recorded for this section.

Ignitron special-purpose ratings do not map cleanly to the standard promoted active-tube fields.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

195X Tesla

Published operating points and test conditions from this source.

SECTION 1

IgnitronPowerSwitch

Other

  • Arc voltage

    15 V

    Published English-language source table

  • Ignitor current maximum

    5 A

    Published English-language source table

  • Ignitor voltage maximum

    300 V

    Published English-language source table

  • Maximum frequency

    1000 Hz

    Published English-language source table

Data set 02

1966 Tesla Tubes

Published operating points and test conditions from this source.

SECTION 1

IgnitronPowerSwitch

Characteristic

  • Arc voltage

    15 V

Other

  • Maximum ignitor current

    5 A

  • Maximum surge current

    1000 A

    Two cycles at 50 Hz

  • Maximum ignitor voltage

    300 V

  • Maximum repetition frequency

    1000 Hz

  • Maximum ambient temperature

    30 degC

  • Minimum ambient temperature

    15 degC