Skip to main content

Power - Triode ·Triode

HY51A

Power transmitting triode intended for RF amplification, oscillation, or related professional service. Manufacturer documentation emphasizes radio-frequency operation, substantial plate loading, and transmitter or industrial applications.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
1
Base
-
Socket code
UX4
Base pins
4
Nominal heater
7.5 V / 3.5 A

Description

2 - 38 HTRONIC Engineering Bulletin 51 - 1 Type HY51A-HY51B PHYSICAL DATA Plate Processed Graphite Grid Molybdenum-Nickel Filament Thoriated Tungsten Insulation Processed Lava Base 4 Pin UX Iso. Plate Lead Large Metal Cap Max., Overall Length 6 9/16" Max, Diameter 2 7/16" Bulb ST-19 Net Weight 3 1/4 oz. INTERELECTRODE CAPACITANCE Grid to Plate 7.5 uuf Grid to Filament 6.0 uuf Plate to Filament 2.0 uuf ELECTRICAL DATA HY51A HY51B Fi{lament Voltage 7.5 Volts 10.0 Volts Filament Current 3.5 Amperes 2.25 Amperes D.C. Plate Voltage 1000. Volts Max. Plate Dissipation 65. Watts Max. Max., Plate Current 155. ma. Max. Grid Current 25, ma. Average Amp. Factor 25 Mutual Conductance 6500 unthos BASE PIN

Socket description

Medium-shell UX 4-contact

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
UX4
Base pins
4
Nominal heater voltage
7.5 V
Nominal heater current
3.5 A
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Triode

X-ray radiationInterelectrode capacitances
Transconductance
0.0065 S
Amplification factor
25
Max plate voltage
1000 V
Max plate dissipation
65 W
Max cathode current
155 mA

Promoted ratings/characteristics from HY51A.pdf.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1944 Hytron

Published operating points and test conditions from this source.

SECTION 1

Triode

Characteristics

  • Heater or filament current

    3.5 A

    Published nominal value