Data set 01
1963 Ferranti
Published operating points and test conditions from this source.
Rectifier
Application
Application
High-voltage half-wave rectifier
CapacitorInputFilter
Other
PIV no-load
40 kV
CapacitorInputFilter
PIV working
36 kV
CapacitorInputFilter
RMS input voltage maximum
15 kV
CapacitorInputFilter
Peak anode current maximum
175 mA
CapacitorInputFilter
Rectified current maximum
25 mA
CapacitorInputFilter
Reservoir capacitance maximum
0.1 uF
CapacitorInputFilter
Supply impedance minimum
27000 ohm
CapacitorInputFilter
Switching delay minimum
5 s
CapacitorInputFilter