Skip to main content

Nixie ·Nixie

HB105

Gas-filled cold-cathode Nixie numerical/readout tube for direct digit indication in electronic instruments and counting equipment.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
1
Base
-
Socket code
B13B
Base pins
-
Nominal heater
-

Description

HB105 is a gas-filled cold-cathode Nixie numerical/readout device. The shared catalog identifies it with the HB105 electrical family, using a maximum ionization voltage of 150 V and a recommended minimum supply of 150 V.

Socket description

B13B Nixie 13-contact

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
B13B
Base pins
-
Nominal heater voltage
-
Nominal heater current
-
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Nixie

X-ray radiationInterelectrode capacitances
Max cathode current
0.8 mA
Regulator minimum current
0.2 mA
Regulator maximum current
0.35 mA
Regulator starting voltage
150 V

Gas-filled cold-cathode 10-position Pixie readout indicator with common anode; ten glow positions are visible through numerical perforations 0 through 9.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1961 Nixie Burroughs

Published operating points and test conditions from this source.

SECTION 1

Nixie

Other

  • Ionization Voltage Maximum

    150 V

  • Supply Voltage Minimum

    150 V

    Catalog minimum supply voltage

  • Cathode Current Peak

    0.8 mA

  • Cathode Current Average

    0.25 mA

  • Individual Cathode Wattage Maximum

    0.08 W

  • Test Supply Voltage

    150 V

  • Test Series Resistor

    82 kOhm

  • Display Size Class

    Standard 10-position readout

  • Recommended Socket

    HSK111

  • Recommended Supply Voltage

    150 V

    Series resistor 82 kOhm

  • Recommended Series Resistor

    82 kOhm

    Supply voltage 150 V

Characteristic

  • Cathode Current Minimum

    0.2 mA

  • Cathode Current Maximum

    0.35 mA

Data set 02

196X Burroughs Nixie

Published operating points and test conditions from this source.

SECTION 1

Nixie

Other

  • Ionization voltage

    150 to - V

    Minimum

  • Cathode current

    0.25 mA

    Average

  • Cathode current

    0.5 mA

    Peak

  • Individual cathode dissipation

    0.08 W

    Maximum

  • Anode supply voltage

    150 V

    BasicCircuit test condition

  • Anode series resistor

    82 kOhm

    BasicCircuit test condition

  • Cathode current

    0.2 to 0.35 mA

    BasicCircuit test condition

  • Number of readout positions

    10 count

    Numerals 0 through 9

  • Position spacing

    36 deg

    Ten glow positions