Data set 01
199X JJ
Published operating points and test conditions from this source.
Rectifier
Other
TransformerSeriesResistancePerPlate
75 ohm
CapacitorInputFilter;50Hz;ACPerPlate=300V
DC Output Current
250 mA
CapacitorInputFilter;50Hz;ACPerPlate=300V
FilterCapacitance
60 uF
CapacitorInputFilter;50Hz;ACPerPlate=300V
DC Output Voltage
330 V
CapacitorInputFilter;50Hz;ACPerPlate=300V
TransformerSeriesResistancePerPlate
125 ohm
CapacitorInputFilter;50Hz;ACPerPlate=400V
DC Output Current
250 mA
CapacitorInputFilter;50Hz;ACPerPlate=400V
FilterCapacitance
60 uF
CapacitorInputFilter;50Hz;ACPerPlate=400V
DC Output Voltage
430 V
CapacitorInputFilter;50Hz;ACPerPlate=400V
TransformerSeriesResistancePerPlate
175 ohm
CapacitorInputFilter;50Hz;ACPerPlate=500V
DC Output Current
200 mA
CapacitorInputFilter;50Hz;ACPerPlate=500V
FilterCapacitance
60 uF
CapacitorInputFilter;50Hz;ACPerPlate=500V
DC Output Voltage
560 V
CapacitorInputFilter;50Hz;ACPerPlate=500V
TransformerSeriesResistancePerPlate
200 ohm
CapacitorInputFilter;50Hz;ACPerPlate=550V
DC Output Current
160 mA
CapacitorInputFilter;50Hz;ACPerPlate=550V
FilterCapacitance
60 uF
CapacitorInputFilter;50Hz;ACPerPlate=550V
DC Output Voltage
640 V
CapacitorInputFilter;50Hz;ACPerPlate=550V
DC Output Current
250 mA
ChokeInputFilter;50Hz;ACPerPlate=300V
ChokeInductance
10 H
ChokeInputFilter;50Hz;ACPerPlate=300V
DC Output Voltage
250 V
ChokeInputFilter;50Hz;ACPerPlate=300V
DC Output Current
250 mA
ChokeInputFilter;50Hz;ACPerPlate=400V
ChokeInductance
10 H
ChokeInputFilter;50Hz;ACPerPlate=400V
DC Output Voltage
330 V
ChokeInputFilter;50Hz;ACPerPlate=400V
DC Output Current
250 mA
ChokeInputFilter;50Hz;ACPerPlate=500V
ChokeInductance
10 H
ChokeInputFilter;50Hz;ACPerPlate=500V
DC Output Voltage
420 V
ChokeInputFilter;50Hz;ACPerPlate=500V
DC Output Current
225 mA
ChokeInputFilter;50Hz;ACPerPlate=550V
ChokeInductance
10 H
ChokeInputFilter;50Hz;ACPerPlate=550V
DC Output Voltage
465 V
ChokeInputFilter;50Hz;ACPerPlate=550V