Data set 01
1955 Marconi
Published operating points and test conditions from this source.
Triode
Other
Series heater voltage
12.6 V
Series heater current
150 mA
Parallel heater voltage
6.3 V
Parallel heater current
300 mA
Maximum plate voltage
300 V
Maximum plate dissipation per section
2.75 W
Typical plate voltage
250 V
Characteristic
Amplification factor
17
Transconductance
2200 uS
Capacitance
Grid-plate capacitance
1.5 pF
Grid-cathode capacitance
1.6 pF
Plate-cathode capacitance
0.5 pF