Data set 01
1955 Marconi
Published operating points and test conditions from this source.
Rectifier
Other
Filament voltage
4 V
Filament current
11 A
Peak inverse voltage
13000 V
Peak cathode/anode current
5 A
Average cathode current
1.25 A
Minimum seasoning/preheat time
1800 s
Single-phase full-wave output voltage
8 kV
Single-phase full-wave output current
2.5 A
Three-phase full-wave output voltage
12.4 kV
Three-phase full-wave output current
3.75 A
Construction
Filling
Mercury vapor