Data set 01
1964 RMA EIA
Published operating points and test conditions from this source.
CameraPickup
Construction
Camera-tube type
Vidicon
Scanned target size
1/2 x 3/8 in
Maximum useful image diagonal
0.62 in
Other
Heater voltage tolerance
+/-10 %
Faceplate illumination maximum
1000 foot-candle
Faceplate temperature maximum
71 C
Target voltage maximum
100 V
Target current peak maximum
0.6 uA
Dark current maximum
0.25 uA
Grid3-and-grid4 voltage maximum
750 V
Grid2 voltage maximum
750 V
Grid1 negative bias maximum
-300 V
Grid1 positive bias maximum
0 V
Heater-cathode voltage maximum heater negative
125 V
Heater-cathode voltage maximum heater positive
10 V
Typical faceplate temperature
30 to 35 C
Typical grid3-and-grid4 voltage
250 to 300 V
Typical grid2 voltage
300 V
Grid1 picture-cutoff voltage
-45 to -100 V
Blanking voltage at grid1 minimum
75 V p-p
Blanking voltage at cathode minimum
20 V p-p
Focus-coil field strength
40 gauss
Alignment-coil field strength
0 to 4 gauss
Average-sensitivity faceplate illumination
1 foot-candle
Average-sensitivity target voltage
30 to 50 V
Average-sensitivity dark current
0.02 uA
Maximum-sensitivity faceplate illumination
0.2 foot-candle
Maximum-sensitivity target voltage
40 to 100 V
Maximum-sensitivity dark current
0.2 uA
Characteristics
Heater current
90 mA
Heater power approximate
0.6 W
Focus method
Magnetic
Deflection method
Magnetic
Resolution minimum at center
600 TV lines
Average gamma
0.65
Capacitance
Anode-to-all capacitance
3.6 pF
Application
Application
Transistorized camera / industrial and live television pickup