Data set 01
1964 RMA EIA
Published operating points and test conditions from this source.
CameraPickup
Construction
Camera-tube type
Vidicon
Field mesh
Separate
Scanned target size
1/2 x 3/8 in
Maximum useful image diagonal
0.62 in
Other
Heater voltage tolerance
+/-10 %
Faceplate illumination maximum
1000 foot-candle
Target voltage maximum
100 V
Target current peak maximum
0.6 uA
Dark current maximum
0.25 uA
Grid4 voltage maximum
1000 V
Grid3 voltage maximum
1000 V
Grid2 voltage maximum
750 V
Grid1 positive bias maximum
0 V
Heater-cathode voltage maximum heater negative
125 V
Heater-cathode voltage maximum heater positive
10 V
Typical faceplate temperature
30 to 35 C
Average-sensitivity faceplate illumination
1 foot-candle
Average-sensitivity target voltage
20 to 40 V
Average-sensitivity dark current
0.02 uA
Maximum-sensitivity faceplate illumination
0.01 foot-candle
Maximum-sensitivity target voltage
35 to 70 V
Maximum-sensitivity dark current
0.2 uA
Grid1 picture-cutoff voltage
-45 to -100 V
Grid2 voltage
300 V
High-resolution grid3 beam-focus voltage
600 V
High-resolution grid4 field-mesh voltage
800 V
High-resolution focus-coil field strength
60 gauss
Characteristics
Heater current
600 mA
Focus method
Magnetic
Deflection method
Magnetic
Resolution capability
1000 TV lines
Amplitude response at 400 TV lines
70 %
Capacitance
Anode-to-all capacitance
3.6 pF
Application
Application
Studio / remote / industrial television camera pickup