Power - Triode ·Triode
GI27A1
Direct-heated pulse triode; 25 kW / 5 MW pulse output; gm 0.075–0.105 A/V.
Directly heatedCold cathodeCommon cathodeDissimilar
- Sections
- 1
- Base
- -
- Socket code
- -
- Base pins
- -
- Nominal heater
- 13 V / 500 A
General specifications
Tube and section characteristics
Properties common to every published source and operating point.
Heater and base
- Base
- -
- Socket code
- -
- Base pins
- -
- Nominal heater voltage
- 13 V
- Nominal heater current
- 500 A
- Parallel heater voltage
- -
- Parallel heater current
- -
- Series capable
- No
Terminal pinout
Electrical assignments shared by every tube using this base designation.
No verified pinout is recorded for this base designation.
Section ratings
1 physical section, each with unique specifications.
Section 1
Triode
X-ray radiationInterelectrode capacitances
- Transconductance
- 0.09 S
- Max plate voltage
- 40000 V
Source-dependent data
Operating conditions by source