Data set 01
196X Ericsson Telephones Ltd
Published operating points and test conditions from this source.
Nixie
Other
Maximum counting rate
20000 pulses/s
Published datasheet value
Nixie ·Nixie
Cold-cathode scale-of-ten counter tube designed to advance a glow discharge sequentially through ten states. It performs electronic counting or sequencing directly within the discharge structure rather than simply illuminating externally selected numeral cathodes.
GC10D is a scale-of-ten counter tube, classified as Nixie for this batch. The supplied datasheet describes its cold-cathode discharge operation and published electrical ratings/operating conditions.
International Octal
General specifications
Properties common to every published source and operating point.
Electrical assignments shared by every tube using this base designation.
No verified pinout is recorded for this base designation.
1 physical section, each with unique specifications.
Section 1
Published cold-cathode ratings and characteristics promoted where applicable.
Source-dependent data
Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.
Data set 01
Published operating points and test conditions from this source.
Maximum counting rate
20000 pulses/s
Published datasheet value
Data set 02
Published operating points and test conditions from this source.
Maximum Anode/Cathode Current
12 mA
Published datasheet value
Minimum/Typical Supply Voltage
420 V
Published datasheet value
Maximum Counting Rate
20 kHz
Published datasheet value
Minimum Anode/Cathode Current
0.7 mA
Published datasheet value
Running/Maintaining Voltage
215 V
Published datasheet value