Data set 01
1951 Mullard Valve and Service Manual
Published operating points and test conditions from this source.
Rectifier
Other
RMS input per anode maximum
500 V
DC output current maximum
250 mA
Peak inverse voltage
1600 V
Rectifier - Full Wave ·Rectifier-Rectifier
Directly heated full-wave power rectifier for substantial DC supplies. Its four-volt filament and high inverse-voltage capability support receiver, amplifier, and general high-voltage electronic power systems.
Directly heated full-wave power rectifier for outputs up to 500 V at 250 mA.
European 4-pin base
General specifications
Properties common to every published source and operating point.
Electrical assignments shared by every tube using this base designation.
No verified pinout is recorded for this base designation.
2 physical sections, each with unique specifications.
Section 1
Full-wave directly heated rectifier; PIV and maximum output current promoted.
Section 2
Physical rectifier section 2; identical section values duplicated per physical-section policy.
Source-dependent data
Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.
Data set 01
Published operating points and test conditions from this source.
RMS input per anode maximum
500 V
DC output current maximum
250 mA
Peak inverse voltage
1600 V
Data set 02
Published operating points and test conditions from this source.
RMS anode voltage
500 V
PerAnode;2x500V
Reservoir capacitance
16 uF
2x500V
Minimum series resistance per anode
200 Ohm
2x500V
Reservoir capacitance
32 uF
2x350V
Data set 03
Published operating points and test conditions from this source.
HeaterOrFilamentVoltage
4 V
HeaterOrFilamentCurrent
4 A
RMSInputVoltagePerAnodeMaximum
500 V
DCOutputCurrentMaximum
250 mA
PeakInverseVoltageMaximum
1800 V
Reservoir Capacitance
16 uF
RMSInput=500V
SeriesResistanceMinimum
200 ohm
RMSInput=500V