Data set 01
1962 ITT
Published operating points and test conditions from this source.
TravelingWave
Other
The F-T3 [1]
41
The F-T341 is a 5 watt pulse traveling wave amplifier tube having 25 db gain
The F-T3 [2]
5
The F-T341 is a 5 watt pulse traveling wave amplifier tube having 25 db gain
The F-T3 [3]
25
The F-T341 is a 5 watt pulse traveling wave amplifier tube having 25 db gain
and [1]
8000
and 8000 to 9600 mc frequency range. It is constructed in a rugged metal
and [2]
9600
and 8000 to 9600 mc frequency range. It is constructed in a rugged metal
element used in F
6996
element used in F-6996, Operation is limited by this grid to pulse service,
Heater Voltage [1]
6.3 V
Heater Voltage 6.3 (£10%) volts
Heater Voltage [2]
10 V
Heater Voltage 6.3 (£10%) volts
Heater Current
2.3 A
Heater Current 2.3 amperes
Maximum Anode Voltage (Note [1]
1 V
Maximum Anode Voltage (Note 1) 3400 wvolts
Maximum Anode Voltage (Note [2]
3400 V
Maximum Anode Voltage (Note 1) 3400 wvolts
Maximum Shell Current (Note [1]
2 A
Maximum Shell Current (Note 2) 20 ma peak
Maximum Shell Current (Note [2]
20 A
Maximum Shell Current (Note 2) 20 ma peak
Maximum Collector Voltage (Note [1]
3 V
Maximum Collector Voltage (Note 3) 3500 wvolts
Maximum Collector Voltage (Note [2]
3500 V
Maximum Collector Voltage (Note 3) 3500 wvolts
Maximum Collector Dissipation (Note [1]
4 W
Maximum Collector Dissipation (Note 4) 10 watts
Maximum Collector Dissipation (Note [2]
10 W
Maximum Collector Dissipation (Note 4) 10 watts
Maximum Grid Voltage (Note
5 V
Maximum Grid Voltage (Note 5)
Maximum Grid Current
6 A
Maximum Grid Current 6 ma peak
Minimum Frequency
8000
Minimum Frequency 8000 mc
Maximum Frequency
9600
Maximum Frequency 9600 mc
Capacitance - Grid to all other elements
15 pF
Capacitance - Grid to all other elements 15 ppf max,
R-F Input and Output Impedance
50
R-F Input and Output Impedance 50 ohm coax.
Glass Temperature
160
Glass Temperature 160 ©C max.
Anode Voltage
3200 V
Anode Voltage 3200 volts
Shell Current
10 A
Shell Current 10 ma peak
Collector Voltage
3200 V
Collector Voltage 3200 wvolts
Collector Current
50 A
Collector Current 50 ma peak
Applied Voltage Pulse
120 V
Applied Voltage Pulse 120 volts peak
Grid Current
3 A
Grid Current 3 ma peak
Power Output
5 W
Power Output 5 watts nominal
Gain
25
Gain 25 db nominal
Note
1 V
Note 1: All voltages shown are with respect to cathode. The shell is
Note
2 V
Note 2: Initial adjustments of voltage and magnetic field may be made at
low duty cycles
20 A
low duty cycles. 20 ma shell current must not be exceeded at maxi-
Note
3
Note 3: The collector is normally connected to the shell. A viewing resistor
Note
5 V
Note 5: Positive voltage must not be applied to the grid in the absence of
Note [1]
7 V
Note 7: The minimum cold insertion loss applies for grid voltage of -10
Note [2]
-10 V
Note 7: The minimum cold insertion loss applies for grid voltage of -10
Base B6 [1]
-63
Base B6-63 Collector Connector UG-23 B/U
Base B6 [2]
23
Base B6-63 Collector Connector UG-23 B/U
Published value
2
2 Heater-Cathode
Published value
6
6 Grid
Published value
10
10 Heater