Data set 01
1962 ITT
Published operating points and test conditions from this source.
Triode
Other
The F-T0
12 V
The F-T012 is a triode designed for use in high voltage pulse operation,
The anode is forced air cooled, capable of dissipating
2.5
The anode is forced air cooled, capable of dissipating 2.5 kilowatts
Filament Voltage
15 V
Filament Voltage 15 volts
Filament Current
36 A
Filament Current 36 amperes
Grid-Plate
142
Grid-Plate 14,2 puf
Grid-Filament
16.3
Grid-Filament 16.3 puf
Plate-Filament
1.9
Plate-Filament 1.9 puf
Plate Dissipation - kilowatts [1]
2.5 kW
Plate Dissipation - kilowatts 2.5 2.0 1.5
Plate Dissipation - kilowatts [2]
2 kW
Plate Dissipation - kilowatts 2.5 2.0 1.5
Plate Dissipation - kilowatts [3]
1.5 kW
Plate Dissipation - kilowatts 2.5 2.0 1.5
Maximum Glass Temperature
180
Maximum Glass Temperature 180° C.
D=C Plate Voltage
17.5 V
D=C Plate Voltage 17.5 kilovolts, max.
D-C Grid Voltage
-5 V
D-C Grid Voltage -5.0 kilovolts, wmax,
Peak Cathode Current
40 A
Peak Cathode Current 40 amperes, max.
Plate Dissipation#
1.2 kW
Plate Dissipation# 1.2 kilowatts
D-C Plate Voltage
15500 V
D-C Plate Voltage 15,500 volts
D=C Grid Voltage (during pulse) =
750 V
D=C Grid Voltage (during pulse) =750 volts
D=C Plate Current
200 mA
D=C Plate Current 0.20 amperes
D=C Grid Current
0 mA
D=C Grid Current .0l3 amperes
Power Qutput, approximate
90 kW
Power Qutput, approximate 90 kilowatts
F-T7
12 W
F-T7012 POWER TRIODE