Data set 01
1962 ITT
Published operating points and test conditions from this source.
Triode
Other
TUBE DATA r
6021 W
TUBE DATA r-6021 POWER
The anode is capable of dissipating
30 kW
The anode is capable of dissipating 30 kw during Continuous Commercial
Filament Voltage
5 V
Filament Voltage 5 volts
Filament Current
260 A
Filament Current 260 amperes
Grid-Plate
53
Grid-Plate 53 uuf
Grid-Filament
48
Grid-Filament 48 puf
Maximum Glass Temperature
180
Maximum Glass Temperature 180°c
D-C Plate Voltage
15 kV
D-C Plate Voltage 15 max, kv
Maximum Signal D-C Plate Current¥
10 A
Maximum Signal D-C Plate Current¥ 10 amperes
Maximum Signal Plate Input#*
60 kW
Maximum Signal Plate Input#* 60 kw
Plate Digsipation*
30 kW
Plate Digsipation* 30 kw
D-C Plate Voltage
10000 V
D-C Plate Voltage 10,000 volts
D-C Grid voltage
-2400 V
D-C Grid voltage -2,400 volts
Peak A-F Grid-to-Grid vVoltage
4680 V
Peak A-F Grid-to-Grid vVoltage 4,680 volts
Zero Signal D-C Plate Current
2 A
Zero Signal D-C Plate Current 2.0 amperes
Maximum Signal D-C Plate Current
9.5 A
Maximum Signal D-C Plate Current 9.5 amperes
Effective Load, Resistance Plate~to-Plate
1870
Effective Load, Resistance Plate~to-Plate 1870 ohms
Maximum Signal Driving Power
0 W
Maximum Signal Driving Power 0 watts
Maximm Signal Power Output
52.5 kW
Maximm Signal Power Output 52.5 kw
D-C Plate Voltage
12500 V
D-C Plate Voltage 12,500 volts
D~C Grid Voltage
-3200 V
D~C Grid Voltage -3,200 volts
Peak A-F grid-to-Grid Voltage
6100 V
Peak A-F grid-to-Grid Voltage 6,100 volts
Zero Signal D-C Plate Current
1.5 A
Zero Signal D-C Plate Current 1.5 amperes
Maximum Signal D-C Plate Current
45 A
Maximum Signal D-C Plate Current 4,5 amperes
Effective Il.oad Resistance Plate-to-Plate T4
0
Effective Il.oad Resistance Plate-to-Plate T400 ohms
Load Power Factor [1]
0 W
Load Power Factor 0 - 100%
Load Power Factor [2]
100 W
Load Power Factor 0 - 100%
Published value [1]
7 W
7 F-6921 POWER TRIODE
Published value [2]
6921 W
7 F-6921 POWER TRIODE