Data set 01
1962 ITT
Published operating points and test conditions from this source.
Triode
Other
oscillator., The anode is capable of dissipating
20
oscillator., The anode is capable of dissipating 20 kilowatts during
Filament Voltage T
5 V
Filament Voltage T.5 volts
Filament Current
107 A
Filament Current 107 amperes
Filament Starting Current
300 A
Filament Starting Current 300 amperes max.
Filament Cold Resistance
1
Filament Cold Resistance .01 ohms
Filament Heating Time
15
Filament Heating Time 15 seconds min.
Grid-Plate
26
Grid-Plate 26 puf
grid-Filament
25
grid-Filament 25 uuf
Plate-Filament
1
Plate-Filament 1.0 ppf
Water Flow on Anode
8
Water Flow on Anode 8 gpm
Glass Temperature (at hottest part)
180
Glass Temperature (at hottest part) 180° C¢. max.
D-C Plate Voltage
15000 V
D-C Plate Voltage 15,000 max, volts
D-C Grid Voltage
-1800 V
D-C Grid Voltage -1,800 max. volts
D-C Plate Current
3.5 A
D-C Plate Current 3.5 max, amperes
D-C @Grid Current
50 A
D-C @Grid Current .50 max. amperes
Plate Input
45
Plate Input 45 max. kilowatts
Plate Dissipation
20 W
Plate Dissipation 20 wax. kilowatts
D~C Plate Voltage
12500 V
D~C Plate Voltage 12,500 volts
D-C Grid Voltage
-1200 V
D-C Grid Voltage -1,200 volts
Peak R-F Grid Voltage
2100 V
Peak R-F Grid Voltage 2,100 volts
D-C Plate Current
3.5 A
D-C Plate Current 3.5 amperes
D-C Grid Current, approximate
45 A
D-C Grid Current, approximate 45 amperes
Driving Power, approximate
900 W
Driving Power, approximate 900 watts
Power Output, approximate
33 W
Power Output, approximate 33 kilowatts
Frequency [1]
27.5
Frequency 27.5 %0 50 Megacycles
Frequency [2]
0
Frequency 27.5 %0 50 Megacycles
Frequency [3]
50
Frequency 27.5 %0 50 Megacycles
Voltage and Plate Input [1]
100 V
Voltage and Plate Input 100 8o 50 Per Cent
Voltage and Plate Input [2]
8 V
Voltage and Plate Input 100 8o 50 Per Cent
Voltage and Plate Input [3]
50 V
Voltage and Plate Input 100 8o 50 Per Cent
F
6800 W
F-6800 POWER TRIODE