Data set 01
1958 Compagnie General
Published operating points and test conditions from this source.
TravelingWave
Characteristics
Frequency minimum
1 GHz
Frequency maximum
2 GHz
Saturated RF output minimum
10 W
Small-signal gain minimum
33 dB
Warmup time
180 s
Construction
Cooling method
Forced air