Skip to main content

Power - Triode (over 1000V 100W) ·Triode

F343AA

Forced-air-cooled Federal power triode for RF amplification, oscillation, and Class B modulation. Approximately 5 kW plate dissipation and 18 kV capability emphasize high-voltage transmitter service with air-cooled construction.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
1
Base
-
Socket code
-
Base pins
-
Nominal heater
21.5 V / 57.5 A

Description

Federal F-343-AA forced-air-cooled power triode for RF power amplifier, oscillator and Class B modulator service; 5 kW anode dissipation.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
-
Nominal heater voltage
21.5 V
Nominal heater current
57.5 A
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Triode

X-ray radiationInterelectrode capacitances
Amplification factor
40
Max plate voltage
18000 V
Max plate dissipation
5000 W
Max cathode current
8 A

Applicable promoted fields mapped from printed headings; specialized microwave/imaging/electrode data retained densely in TUBE_SECTION_PARAMETER.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1962 ITT

Published operating points and test conditions from this source.

SECTION 1

Triode

Other

  • Filament Starting Current

    115 A

  • Peak Cathode Current

    8 A

  • Grid-Plate Capacitance

    23.5 pF

  • Grid-Filament Capacitance

    16.6 pF

  • Plate-Filament Capacitance

    1.9 pF

  • RF Frequency Full Rating Maximum

    4 MHz

  • Required Anode Airflow

    600 cfm

Data set 02

1962 ITT Industrial and Transmitting Tubes

Published operating points and test conditions from this source.

SECTION 1

Triode

Other

  • FilamentStartingCurrent

    115 A

  • Peak Cathode Current

    8 A

  • AnodeCoolingMethod

    Forced Air

  • MaximumOperatingFrequency

    4 MHz

  • Maximum Anode Dissipation

    5000 W

    Absolute maximum / applicable service

Capacitance

  • GridPlateCapacitance

    23.5 pF

  • GridFilamentCapacitance

    16.6 pF