Skip to main content

Power - Triode (over 1000V 100W) ·Triode

F134

Federal very-high-power water-cooled triode for RF amplification, oscillation, and Class B modulation. Approximately 150 kW plate dissipation and 20 kV capability place it among extremely large broadcast, communications, and industrial power tubes.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
1
Base
-
Socket code
-
Base pins
-
Nominal heater
25 V / 650 A

Description

Federal F-134 very-high-power water-cooled triode for RF amplifier, oscillator and Class B modulator service; 150 kW anode dissipation.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
-
Nominal heater voltage
25 V
Nominal heater current
650 A
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Triode

X-ray radiationInterelectrode capacitances
Amplification factor
21
Max plate voltage
20000 V
Max plate dissipation
150000 W
Max grid dissipation
4000 W
Max cathode current
24 A

Highest applicable published maximum ratings promoted; service-specific operating points preserved as parameters.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1962 ITT

Published operating points and test conditions from this source.

SECTION 1

Triode

Characteristic

  • Amplification factor

    21

Other

  • Maximum plate voltage

    20000 V

  • Maximum plate dissipation

    150000 W

  • Maximum cathode/plate current

    24 A

  • Maximum frequency for full ratings

    22 MHz

  • Typical RF plate voltage

    18000 V

  • Typical RF plate current

    9.6 A

  • Typical RF driving power

    1.2 kW

  • Typical RF output power

    108 kW

Capacitance

  • Grid-plate capacitance

    105 pF

  • Grid-filament capacitance

    140 pF

  • Plate-filament capacitance

    4 pF

Construction

  • Cooling method

    Water

Data set 02

1962 ITT Industrial and Transmitting Tubes

Published operating points and test conditions from this source.

SECTION 1

Triode

Other

  • FilamentStartingCurrent

    1000 A

  • Peak Cathode Current

    120 A

  • AnodeCoolingMethod

    Water

  • MaximumOperatingFrequency

    22 MHz

  • Maximum Anode Dissipation

    150000 W

    Absolute maximum / applicable service

Capacitance

  • GridPlateCapacitance

    105 pF

  • PlateFilamentCapacitance

    4 pF