Skip to main content

Power - Triode (over 1000V 100W) ·Triode

F132A

Federal radiation-cooled power triode designed particularly for modulator service. Approximately 600 W plate dissipation and multi-kilovolt plate capability emphasize high-current audio-frequency power for moderate transmitter modulation applications.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
1
Base
-
Socket code
-
Base pins
-
Nominal heater
11 V / 13 A

Description

Federal F-132-A radiation-cooled power triode designed for modulator service, with a 600 W anode dissipation rating.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
-
Nominal heater voltage
11 V
Nominal heater current
13 A
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Triode

X-ray radiationInterelectrode capacitances
Amplification factor
10
Max plate voltage
3500 V
Max plate dissipation
600 W
Max grid dissipation
500 W
Max cathode current
317 mA

Highest applicable published maximum ratings promoted; service-specific operating points preserved as parameters.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1962 ITT

Published operating points and test conditions from this source.

SECTION 1

Triode

Characteristic

  • Amplification factor

    10

Other

  • Maximum plate voltage

    3500 V

  • Maximum plate dissipation

    600 W

  • Maximum cathode/plate current

    317 mA

  • Maximum frequency for full ratings

    0.02 MHz

  • Typical Class-A plate voltage

    3500 V

  • Typical maximum-signal plate current

    317 mA

Capacitance

  • Grid-plate capacitance

    15 pF

  • Grid-filament capacitance

    120 pF

  • Plate-filament capacitance

    5.5 pF

Construction

  • Cooling method

    Radiation

Data set 02

1962 ITT Industrial and Transmitting Tubes

Published operating points and test conditions from this source.

SECTION 1

Triode

Other

  • AnodeCoolingMethod

    Radiation

  • Maximum Anode Dissipation

    600 W

    Absolute maximum / applicable service

Capacitance

  • GridPlateCapacitance

    15 pF

  • GridFilamentCapacitance

    12 pF