Data set 01
1962 ITT
Published operating points and test conditions from this source.
Triode
Characteristic
Amplification factor
40.5
Other
Maximum plate voltage
20000 V
Maximum plate dissipation
20000 W
Maximum cathode/plate current
7 A
Maximum frequency for full ratings
20 MHz
Typical RF plate voltage
18000 V
Typical RF output power
55 kW
Capacitance
Grid-plate capacitance
40 pF
Grid-filament capacitance
46 pF
Plate-filament capacitance
5.6 pF
Construction
Cooling method
Forced air
