Power - Triode (over 1000V 100W) ·Triode

F124A

Industrial transmitting power triode intended for RF amplification, oscillation, or modulation. Manufacturer data emphasize substantial RF output, professional transmitter operation, and power-handling construction rather than receiving-tube service.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
1
Base
-
Socket code
-
Base pins
-
Nominal heater
27.2 V / 205.5 A

Description

Federal F-124-A water-cooled power triode for RF amplifier, oscillator and Class B modulator service; 40 kW anode dissipation.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
-
Nominal heater voltage
27.2 V
Nominal heater current
205.5 A
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Triode

X-ray radiationInterelectrode capacitances
Amplification factor
40.5
Max plate voltage
20000 V
Max plate dissipation
40000 W
Max grid dissipation
3000 W
Max cathode current
7 A

Highest applicable published maximum ratings promoted; service-specific operating points preserved as parameters.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1962 ITT

Published operating points and test conditions from this source.

SECTION 1

Triode

Characteristic

  • Amplification factor

    40.5

Other

  • Maximum plate voltage

    20000 V

  • Maximum plate dissipation

    40000 W

  • Maximum cathode/plate current

    7 A

  • Maximum frequency for full ratings

    20 MHz

  • Typical RF plate voltage

    18000 V

  • Typical RF plate current

    6 A

  • Typical RF output power

    80 kW

Capacitance

  • Grid-plate capacitance

    35 pF

  • Grid-filament capacitance

    46 pF

  • Plate-filament capacitance

    5.6 pF

Construction

  • Cooling method

    Water

Data set 02

1962 ITT Industrial and Transmitting Tubes

Published operating points and test conditions from this source.

SECTION 1

Triode

Other

  • FilamentStartingCurrent

    308 A

  • Peak Cathode Current

    35 A

  • AnodeCoolingMethod

    Water

  • MaximumOperatingFrequency

    20 MHz

  • Maximum Anode Dissipation

    40000 W

    Absolute maximum / applicable service

Capacitance

  • GridPlateCapacitance

    35 pF

  • PlateFilamentCapacitance

    5.6 pF