Skip to main content

Power - Triode (over 1000V 100W) ·Triode

F110X

Industrial transmitting power triode intended for RF amplification, oscillation, or modulation. Manufacturer data emphasize substantial RF output, professional transmitter operation, and power-handling construction rather than receiving-tube service.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
1
Base
-
Socket code
-
Base pins
-
Nominal heater
28 V / 51 A

Description

Federal F-110-X water-cooled power triode for radio-frequency power-amplifier and oscillator service, with a 25 kW dissipation anode.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
-
Nominal heater voltage
28 V
Nominal heater current
51 A
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Triode

X-ray radiationInterelectrode capacitances
Amplification factor
40
Max plate voltage
15000 V
Max plate dissipation
25000 W
Max grid dissipation
5000 W
Max cathode current
2.5 A

Highest applicable published maximum ratings promoted; service-specific operating points preserved as parameters.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1962 ITT

Published operating points and test conditions from this source.

SECTION 1

Triode

Characteristic

  • Amplification factor

    40

Other

  • Maximum plate voltage

    15000 V

  • Maximum plate dissipation

    25000 W

  • Maximum cathode/plate current

    2.5 A

  • Maximum frequency for full ratings

    20 MHz

Capacitance

  • Grid-plate capacitance

    30 pF

  • Grid-filament capacitance

    20 pF

  • Plate-filament capacitance

    2.7 pF

Construction

  • Cooling method

    Water

Data set 02

1962 ITT Industrial and Transmitting Tubes

Published operating points and test conditions from this source.

SECTION 1

Triode

Other

  • FilamentStartingCurrent

    102 A

  • Peak Cathode Current

    12.5 A

  • AnodeCoolingMethod

    Water

  • MaximumOperatingFrequency

    3 MHz full rating; 20 MHz reduced rating

  • Maximum Anode Dissipation

    25000 W

    Absolute maximum / applicable service