Skip to main content

Specialized - Magnetron ·Magnetron

F1103

Variable-frequency forced-air-cooled X-band pulsed magnetron producing about 220 kW nominal peak RF output. It is designed as a tunable high-power microwave pulse oscillator rather than a continuous-wave source.

Directly heatedCold cathodeCommon cathodeDissimilarSpecialized
Sections
1
Base
-
Socket code
-
Base pins
-
Nominal heater
-

Description

Variable-frequency X-band pulsed magnetron with about 220 kW nominal peak output and forced-air cooling.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
-
Nominal heater voltage
-
Nominal heater current
-
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Magnetron

X-ray radiationInterelectrode capacitances

No fixed ratings are recorded for this section.

Magnetron oscillator section; frequency, pulse/CW power, anode, heater and cooling data retained as parameters.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1958 Compagnie General

Published operating points and test conditions from this source.

SECTION 1

Magnetron

Characteristics

  • Frequency minimum

    8500 MHz

  • Frequency maximum

    9600 MHz

  • Peak RF output minimum

    200 kW

    Pulse

  • Peak RF output nominal

    220 kW

    Pulse

  • Warmup time

    180 s

Construction

  • Cooling method

    Forced air