Skip to main content

Power - Triode ·Triode

F1091

Experimental very-high-power directly heated triode developed for hard-tube modulator service and demonstrated at more than 50 MW peak output.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
1
Base
-
Socket code
-
Base pins
-
Nominal heater
31 V / 975 A

Description

The ITT F1091 is a very-high-power directly heated triode developed for hard-tube modulator service and demonstrated at more than 50 MW peak output.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
-
Nominal heater voltage
31 V
Nominal heater current
975 A
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Triode

X-ray radiationInterelectrode capacitances
Max plate voltage
65000 V
Max cathode current
1340 A

Source is a technical news/test sheet rather than a full production datasheet; published test conditions are preserved. ITT F1091 experimental directly heated high-power modulator triode using a thoriated-tungsten mesh cathode. Documented tests at 65 kV / 900 A peak and 55 kV / 1340 A peak gave approximately 50.4 MW and 52 MW output pulses respectively. These currents and voltages are pulse test conditions, not unrestricted continuous cathode or anode limits. ITT also reported 390 kW plate dissipation and more than 90 MW peak pulse output in a separate 1968 announcement.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1962 ITT

Published operating points and test conditions from this source.

SECTION 1

Triode

Characteristic

  • Filament power

    30 kW

Other

  • Peak power output condition 1

    50.4 MW

    Condition1

  • Peak power output condition 2

    52 MW

    Condition2

  • Plate supply voltage

    65 kV

    Condition1

  • Plate supply voltage

    55 kV

    Condition2

  • Output pulse voltage

    56 kV

    Condition1

  • Output pulse voltage

    38.8 kV

    Condition2

  • Peak plate current

    900 A

    Condition1

  • Peak plate current

    1340 A

    Condition2

  • Peak positive grid voltage

    1400 V

    Condition1

  • Peak positive grid voltage

    1800 V

    Condition2

  • Peak grid current

    170 A

    Condition1

  • Peak grid current

    200 A

    Condition2

  • Load resistance

    62 ohm

    Condition1

  • Load resistance

    29 ohm

    Condition2

  • Pulse duration

    1000 us

  • Duty factor

    0.01