Data set 01
1961 AEI Industrial Valves
Published operating points and test conditions from this source.
Rectifier
Other
CondensedMercuryTemperatureRange
25 to 70 C
MaximumOperatingFrequency
150 Hz
MaximumBiphaseOutputVoltage
6.3 kV
TwoTubes
MaximumBiphaseOutputCurrent
6 A
TwoTubes
MaximumSurgeCathodeCurrent
150 A
0.1s max
Peak Cathode Current
15 A
PIV=20kV;MercuryTemp=25-55C
Average Cathode Current
3 A
PIV=20kV;MercuryTemp=25-55C;MaxAverageTime=10s
Peak Cathode Current
18 A
PIV=15kV;MercuryTemp=25-60C
Average Cathode Current
4 A
PIV=15kV;MercuryTemp=25-60C;MaxAverageTime=10s
Peak Cathode Current
20 A
PIV=10kV;MercuryTemp=25-65C
Average Cathode Current
5 A
PIV=10kV;MercuryTemp=25-65C;MaxAverageTime=10s
Peak Cathode Current
25 A
PIV=5kV;MercuryTemp=25-70C
Average Cathode Current
6 A
PIV=5kV;MercuryTemp=25-70C;MaxAverageTime=10s