Skip to main content

Specialized - Magnetron ·Magnetron

EM1086

Ruggedized ceramic-and-metal packaged voltage-tunable magnetron covering 940–1060 MHz and delivering at least 15 W into 50 ohms. Its electron-injection design and three-terminal output circuit support stable, controllable microwave oscillator operation.

Directly heatedCold cathodeCommon cathodeDissimilarSpecialized
Sections
1
Base
-
Socket code
-
Base pins
-
Nominal heater
6.3 V / 1 A

Description

The Eimac EM-1086 is a ruggedized, ceramic and metal packaged voltage- tunable magnetron capable of delivering a minimum output power of 15 watts into a 50 ohm termination over the frequency range of 940-1060 megacycles. Eimac's three terminal YVTM circuit has been used in this tube to give a more uniform output circuit with the added advantage of one-third more heat dissipating area extending out of the YTM envelope. The electron injection design incorporated in this magnetron minimizes

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
-
Nominal heater voltage
6.3 V
Nominal heater current
1 A
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Magnetron

X-ray radiationInterelectrode capacitances
Max plate voltage
2500 V

Promoted fields populated only where the published value maps directly to the schema; device-specific values retained as parameters.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1962 Eimac

Published operating points and test conditions from this source.

SECTION 1

Magnetron

Other

  • The Eimac EM

    1086

    The Eimac EM-1086 is a ruggedized, ceramic and metal packaged voltage-

  • tunable magnetron capable of delivering a minimum output power of

    15 W

    tunable magnetron capable of delivering a minimum output power of 15 watts

  • into a [1]

    50 MHz

    into a 50 ohm termination over the frequency range of 940-1060 megacycles.

  • into a [2]

    940 MHz

    into a 50 ohm termination over the frequency range of 940-1060 megacycles.

  • into a [3]

    -1060 MHz

    into a 50 ohm termination over the frequency range of 940-1060 megacycles.

  • Warm-up Time

    30 s

    Warm-up Time - 30 seconds

  • Heater: Voltage (ACorDC; - - - . <« . <« =« <« =« <« =« =«

    6.3 V

    Heater: Voltage (ACorDC; - - - . <« . <« =« <« =« <« =« =« 6.3 volts

  • Current - - - - . . < . . . < [1]

    4 A

    Current - - - - . . < . . . < 4 - 4 e - 1.0 ampere

  • Current - - - - . . < . . . < [2]

    4 A

    Current - - - - . . < . . . < 4 - 4 e - 1.0 ampere

  • Current - - - - . . < . . . < [3]

    1 A

    Current - - - - . . < . . . < 4 - 4 e - 1.0 ampere

  • Minimum Output Power - e e e e e e e e e e e e

    15 W

    Minimum Output Power - e e e e e e e e e e e e . 15 watts

  • Frequency Range - . . . . . . . < [1]

    940 MHz

    Frequency Range - . . . . . . . < . . . . 940 to 1060 megacycles

  • Frequency Range - . . . . . . . < [2]

    1060 MHz

    Frequency Range - . . . . . . . < . . . . 940 to 1060 megacycles

  • Anode Voltage* - . . . . . . . .. . - .+

    2500 V

    Anode Voltage* - . . . . . . . .. . - .+ . . - . 2500 volts

  • Cathode Current e

    35 mA

    Cathode Current e 35 milliamperes

  • Injection Anode Voltage*

    750 V

    Injection Anode Voltage* - . . . . . . - . . . - - 750 volts

  • Injection Anode Current

    1

    Injection Anode Current . . . . . . - . . . . - . . 1 milliampere

  • Frequency Range - - . - - . . . . . . < [1]

    940 MHz

    Frequency Range - - . - - . . . . . . < . . 940-1060 megacycles

  • Frequency Range - - . - - . . . . . . < [2]

    -1060 MHz

    Frequency Range - - . - - . . . . . . < . . 940-1060 megacycles

  • Anode Voltage* (Note [1]

    1 V

    Anode Voltage* (Note 1) - - . . . . .« . - . . . 1840-2075 volts

  • Anode Voltage* (Note [2]

    1840 V

    Anode Voltage* (Note 1) - - . . . . .« . - . . . 1840-2075 volts

  • Anode Voltage* (Note [3]

    -2075 V

    Anode Voltage* (Note 1) - - . . . . .« . - . . . 1840-2075 volts

  • Cathode Current - - . . . - . < =« =« =« . < <« [1]

    21 mA

    Cathode Current - - . . . - . < =« =« =« . < <« 21 - 25 milliamperes

  • Cathode Current - - . . . - . < =« =« =« . < <« [2]

    25 mA

    Cathode Current - - . . . - . < =« =« =« . < <« 21 - 25 milliamperes

  • Typical Power Output [1]

    16 W

    Typical Power Output . - - . . - . . . - - - . 16-16 watts

  • Typical Power Output [2]

    -16 W

    Typical Power Output . - - . . - . . . - - - . 16-16 watts

  • Anode FM Sensitivity - . . - . . .- .+

    50

    Anode FM Sensitivity - . . - . . .- .+ . . - . . .50 Me/volt

  • Injection Anode Voltage

    500 V

    Injection Anode Voltage - - - . . . . . - . - . . 500 volts

  • Injection Anode Current

    2 mA

    Injection Anode Current - .- - . . - - . . . . . . .02 milliamperes

  • Heater Current {AC) . . .. . . . .. . . .« =«

    800 mA

    Heater Current {AC) . . .. . . . .. . . .« =« . . 0.8 amperes

  • Note

    1

    Note 1. The operating frequency is determined by the Anode Voltage.

  • Published value [1]

    1086

    1086 magnet temperature does not exceed 70°C.

  • Published value [2]

    70

    1086 magnet temperature does not exceed 70°C.

  • The heater voltage should be maintained within [1]

    5 V

    The heater voltage should be maintained within - 5% of the rated value of 6.3 volts if variations in per-

  • The heater voltage should be maintained within [2]

    6.3 V

    The heater voltage should be maintained within - 5% of the rated value of 6.3 volts if variations in per-

  • Temperature Stability: The permanent magnet for the EM

    1086

    Temperature Stability: The permanent magnet for the EM-1086 has been temperature stabilized to minimize

  • operating frequency of [1]

    1000 MHz

    operating frequency of 1,000 megacycles, the temperature/frequency coefficient is typically 200 kilocycles

  • operating frequency of [2]

    200 MHz

    operating frequency of 1,000 megacycles, the temperature/frequency coefficient is typically 200 kilocycles

  • INJECTION ANODE VOLTAGE:=

    380

    INJECTION ANODE VOLTAGE:=380V .

  • power '

    3

    power '3