Data set 01
1958 Electrons Inc
Published operating points and test conditions from this source.
Thyratron
Other
Continuous DC anode current
1 A
Overload anode current
1 A
LessThan3Seconds
Continuously recurring peak anode current
8 A
Peak inverse voltage
700 V
Peak forward voltage
450 V
Maximum negative grid voltage
100 V
Construction
Gas filling
Xenon
Anode material
Tantalum
Capacitance
Grid-anode capacitance
2 pF
Grid-filament capacitance
7.5 pF
Characteristic
Critical grid current maximum
5 uA
Deionization time maximum
1000 us