Data set 01
1951 Mullard Valve and Service Manual
Published operating points and test conditions from this source.
Pentode
Application
Service
Audio power output
Triode-connected operation
Published
TriodeConnection
Power - Pentode Single (NOT beam) (under 10W) ·Pentode
Low-current-heater output pentode for AC/DC and automobile-radio audio stages.
Output pentode with 200 mA heater for AC/DC and car-radio audio output service. Published heater, characteristics, ratings and application information were read from the supplied Mullard sheet.
International Octal
General specifications
Properties common to every published source and operating point.
Electrical assignments shared by every tube using this base designation.
No verified pinout is recorded for this base designation.
1 physical section, each with unique specifications.
Section 1
Published source values promoted where applicable; additional values retained as parameters.
Source-dependent data
Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.
Data set 01
Published operating points and test conditions from this source.
Service
Audio power output
Triode-connected operation
Published
TriodeConnection
Data set 02
Published operating points and test conditions from this source.
Anode current
32 mA
ClassA
Screen current
5 mA
ClassA
Load resistance
8000 ohm
ClassA
Output power
3.6 W
ClassA
Push-pull output power
7 W
PushPull; TwoTubes