Skip to main content

Rectifier - Half Wave ·Rectifier

EL16F

High-current directly heated xenon half-wave rectifier with tantalum anode. Its massive filament and gas-assisted conduction provide roughly sixteen amperes for low-voltage heavy industrial supplies.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
1
Base
-
Socket code
-
Base pins
-
Nominal heater
2.5 V / 36 A

Description

EL16F is a half-wave xenon rectifier tube using tantalum anode and xenon gas filling. The datasheet publishes filament, anode-current, inverse-voltage, arc-drop and operating ratings.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
-
Nominal heater voltage
2.5 V
Nominal heater current
36 A
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Rectifier

X-ray radiationInterelectrode capacitances
Max cathode current
16 A
Rectifier peak inverse voltage
620 V
Rectifier nominal output current
16 A
Rectifier peak forward current
96 A
Rectifier forward voltage drop
7 V
Rectifier warm-up time
180 s

Xenon rectifier section.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1942 Electrons Inc

Published operating points and test conditions from this source.

SECTION 1

Rectifier

Other

  • D-c. Meter Value - Continuous

    16 A

  • Oscillograph Peak - Continuously Recurring

    96 A

  • Peak Inverse Voltage

    620 V

  • Filament Voltage

    2.5 V

  • Filament Current

    36 A

  • Heating Time Minimum

    3 min

  • Maximum Short Circuit Current

    1000 A

  • Maximum Commutation Factor

    0.66 V/us x A/us

Characteristics

  • Average Arc Drop

    7 V

Data set 02

1958 Electrons Inc

Published operating points and test conditions from this source.

SECTION 1

Rectifier

Other

  • Continuous DC anode current

    16 A

  • Overload anode current

    32 A

    LessThan10Seconds

  • Continuously recurring peak anode current

    96 A

  • Peak inverse voltage

    620 V

Characteristic

  • Minimum filament heating time

    180 s

  • Average arc drop, average tube

    7 V

  • Average arc drop, highest/end-of-life tube

    10 V

  • Filament current tolerance

    3.5 A

Construction

  • Gas filling

    Xenon

  • Anode material

    Tantalum