Data set 01
1999 Philips E-Z
Published operating points and test conditions from this source.
Pentode
Other
Heater voltage
6.3 V
Heating
Heater current
200 mA
Heating
Max. Anodenkaltspannung . . . . . . . . . ... .. Vao = max
550 V
Limiting values
Max. Anodenspannung . . . . . . . . .. ... .. Ve == max
300 V
Limiting values
Max. Schirmgitterkaltspannung . . . . . . . . . . . .. Vg2e = max
550 V
Limiting values
Max. Schirmgitterspannung . . . . . . . . . . . .. .. Viz = max
300 V
Limiting values
Max. Schirmgitterbelastung . . . . . . . . . . . ... W2 = max
0.4 W
Limiting values
Max, Kaltspannung am Fluoreszenzschirm . . . . . . . . Vso = max,
550 V
Limiting values
Max. Spannung am Fluoreszenzschirm . . . . . . . . .. Vi = max
300 V
Limiting values
Max. Kathodenstrom . . . . . ... ... ... ... I, = max
5 mA
Limiting values
Characteristic
Vo =
130 V
Published datasheet value
Vo
250 V
Published datasheet value
punktkurve fir ¥b =
250 V
Published datasheet value
S]n(f groBere Slz;a'llgltnungb. Ohm und ¥b ==
250 V
Published datasheet value
Heizstrom . . . . . . . . . . ¢ . . v v .. .. I =
200 A
Published datasheet value
sowie des Fluoreszenzschirmes . Ve =V, =
250 V
Published datasheet value
gelten Zustand e e e e e e e — Vi = —
20 V
Published datasheet value
Anodenstrom e
8 mA
Published datasheet value
Schirmgitterstrom . . e
0.6 mA
Published datasheet value
Strom zum F]uoreszenzschu:m
0.65 mA
Published datasheet value
Anodenspannung
146 V
Published datasheet value
WY Vp =
180 V
Published datasheet value
Min, Spannung am Fluoreszenzschirm . . . . . . . . . . Vi = min
200 V
Published datasheet value
Published electrical value
13 V
Published datasheet value