Data set 01
1951 Mullard Valve and Service Manual
Published operating points and test conditions from this source.
Pentode
Characteristics
Cutoff characteristic
Variable-mu
Application
Application
HF amplification
Voltage Pentode - Remote Cutoff (single) ·Pentode
Miniature variable-mu RF pentode for controlled RF and IF amplification in communications and professional receiver equipment.
Miniature variable-mu RF pentode for controlled RF and IF amplification. Published heater, characteristics, ratings and application information were read from the supplied Mullard sheet.
Miniature 7-contact
General specifications
Properties common to every published source and operating point.
Electrical assignments shared by every tube using this base designation.
No verified pinout is recorded for this base designation.
1 physical section, each with unique specifications.
Section 1
Published ratings/characteristics promoted from the approved source.
Source-dependent data
Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.
Data set 01
Published operating points and test conditions from this source.
Cutoff characteristic
Variable-mu
Application
HF amplification
Data set 02
Published operating points and test conditions from this source.
HeaterVoltageNominal
6.3 V
Nominal
HeaterCurrentNominal
200 mA
Nominal
Maximum Plate Voltage
250 V
Maximum Screen Voltage
250 V
Maximum Plate Dissipation
2.5 W
Transconductance
4500 µS
Typical
Data set 03
Published operating points and test conditions from this source.
Input capacitance
4.5 pF
Shielded socket
Output capacitance
7 pF
Shielded socket
Anode current
8 mA
Va=250V; Vg2=150V
Screen current
2 mA
Va=250V; Vg2=150V
Maximum operating frequency
160 Mc/s
Data set 04
Published operating points and test conditions from this source.
Heater voltage
6.3 V
Published heater rating
Heater current
200 mA
Published heater rating
Transconductance
2100 µS
RForIFAmplifier
Plate voltage
250 V
RForIFAmplifier
Screen voltage
100 V
RForIFAmplifier
Plate current
7.5 mA
RForIFAmplifier
Data set 05
Published operating points and test conditions from this source.
4.8
5 pF
Published in approved EF92 target datasheet entry; Section1
Cout 6.3
6.5 pF
Published in approved EF92 target datasheet entry; Section1
Ca - gl < 15 <
0.01 pF
Published in approved EF92 target datasheet entry; Section1
Cll - k 2.3
2.3 pF
Published in approved EF92 target datasheet entry; Section1
P g2 max
600 mW
Published in approved EF92 target datasheet entry; Section1
I k max
12 mA
Published in approved EF92 target datasheet entry; Section1
Data set 06
Published operating points and test conditions from this source.
Heater voltage
6.3 V
Heating
Heater current
300 mA
Heating
Maximum plate voltage
300 V
Promoted published datasheet value
Maximum screen voltage
300 V
Promoted published datasheet value
Maximum screen dissipation
0.6 W
Promoted published datasheet value
Transconductance
2500 µS
Promoted published datasheet value
Heizung : indirekt durch Wechsel= Ve =
6.3 V
Published datasheet value
oder Gleichstrom; Ip =
200 mA
Published datasheet value
Vg = 250
250 v
Published datasheet value
Vg2 = 150
200 v
Published datasheet value
Vg3 = 0
0 v
Published datasheet value
s = 2,5 2,5
0.005 mA/V
Published datasheet value
Capacitances - Cg1 =
4.5 pF
Capacitances
Capacités c =
6.5 pF
Capacitances
Cag1 =
0.007 pF
Capacitances