Data set 01
1951 Mullard Valve and Service Manual
Published operating points and test conditions from this source.
Triode
Characteristic
Heater Voltage
6.3 V
Heater Current
400 mA
Voltage - Dual Triode (similar) ·Triode-Triode
High-gain double triode with separate cathodes, intended for paraphase audio-frequency voltage amplification and related low-level AF amplifier circuits.
High-gain double triode with separate cathodes for paraphase audio-frequency voltage amplifiers.
International Octal
General specifications
Properties common to every published source and operating point.
Electrical assignments shared by every tube using this base designation.
No verified pinout is recorded for this base designation.
2 physical sections, each with unique specifications.
Section 1
Published Mullard ratings and characteristics promoted from the supplied source.
Section 2
Second physical triode section; added to align rows with SectionCount.
Source-dependent data
Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.
Data set 01
Published operating points and test conditions from this source.
Heater Voltage
6.3 V
Heater Current
400 mA
Data set 02
Published operating points and test conditions from this source.
Plate voltage
250 V
Grid voltage
-2.5 V
Plate current
2.3 mA
Transconductance
2 mA/V
Amplification factor
68
Plate voltage maximum
300 V
Plate dissipation maximum
1.5 W
Cathode current maximum
8 mA
Inter-section plate capacitance
0.75 pF
Plate-grid capacitance
2.5 pF
Input capacitance
3 pF
Output capacitance section 1
1 pF
Output capacitance section 2
1.3 pF
Application
Paraphase AF voltage amplifier