Data set 01
1951 Mullard Valve and Service Manual
Published operating points and test conditions from this source.
Triode
Characteristic
Heater Voltage
6.3 V
Heater Current
950 mA
Power - TV Vertical Output ·Triode-Triode
Low-impedance double triode designed for television frame time-base oscillator and current-amplifier service, combining moderate gain with relatively high cathode-current capability.
Low-impedance double triode for television frame time-base oscillator and current-amplifier service.
International Octal
General specifications
Properties common to every published source and operating point.
Electrical assignments shared by every tube using this base designation.
No verified pinout is recorded for this base designation.
2 physical sections, each with unique specifications.
Section 1
Published Mullard ratings and characteristics promoted from the supplied source.
Section 2
Second physical triode section; added to align rows with SectionCount.
Source-dependent data
Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.
Data set 01
Published operating points and test conditions from this source.
Heater Voltage
6.3 V
Heater Current
950 mA
Data set 02
Published operating points and test conditions from this source.
Plate voltage
250 V
Grid voltage
-16 V
Plate current
10 mA
Transconductance
2.2 mA/V
Amplification factor
11.5
Plate voltage maximum
300 V
Plate dissipation maximum
3.25 W
Cathode current maximum
50 mA
Inter-section plate capacitance
0.48 pF
Plate-grid capacitance each section
4 pF
Grid-cathode capacitance each section
3.5 pF
Plate-cathode capacitance each section
1.8 pF
Application
TV frame time-base oscillator / current amplifier