Skip to main content

Voltage - Triode (single high frequency) ·Triode

EC98

UHF triode intended for grounded-grid receiver amplifiers.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
1
Base
-
Socket code
B7G
Base pins
-
Nominal heater
6.3 V / 300 mA

Description

UHF triode intended for grounded-grid receiver amplifiers.

Socket description

Miniature 7-contact

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
B7G
Base pins
-
Nominal heater voltage
6.3 V
Nominal heater current
300 mA
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Triode

X-ray radiationInterelectrode capacitances
Plate resistance
3700 Ω
Transconductance
0.0135 S
Amplification factor
50
Max plate voltage
150 V
Max plate dissipation
2.2 W

Published ratings and characteristics promoted from the supplied Brimar source.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1958 Mullard Receiving Tubes

Published operating points and test conditions from this source.

SECTION 1

Triode

Characteristic

  • Heater Voltage

    6.3 V

  • Heater Current

    300 mA

Data set 02

1963 Mullard

Published operating points and test conditions from this source.

SECTION 1

Triode

Application

  • Application

    UHF/VHF oscillator or amplifier

Characteristics

  • Plate voltage

    150 V

  • Plate current

    13.5 mA

  • Grid voltage

    -1.35 V

  • Transconductance

    13.5 mA/V

  • Amplification factor

    50

  • Plate resistance

    3700 ohm

  • Grid cutoff at 60uA

    -15 V