Skip to main content

Voltage - Triode (single high frequency) ·Triode

EC91

Miniature screened grounded-grid triode for VHF/UHF amplifier service.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
1
Base
-
Socket code
B7G
Base pins
-
Nominal heater
6.3 V / 300 mA

Description

Miniature screened grounded-grid triode for VHF/UHF amplifier service.

Socket description

Miniature 7-contact

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
B7G
Base pins
-
Nominal heater voltage
6.3 V
Nominal heater current
300 mA
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Triode

X-ray radiationInterelectrode capacitances
Plate resistance
12000 Ω
Transconductance
0.0085 S
Amplification factor
100
Max plate voltage
250 V
Max plate dissipation
2.5 W
Max cathode current
15 mA

Grounded-grid triode for ultra-short-wave service to about 250 MHz.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1951 Mullard Valve and Service Manual

Published operating points and test conditions from this source.

SECTION 1

Triode

Characteristic

  • Heater Voltage

    6.3 V

  • Heater Current

    300 mA

Other

  • Plate Voltage

    250 V

    GroundedGrid

Data set 02

1958 Mullard Receiving Tubes

Published operating points and test conditions from this source.

SECTION 1

Triode

Characteristic

  • Heater Voltage

    6.3 V

  • Heater Current

    300 mA

  • Application

    Grounded-grid UHF amplifier

Data set 03

1963 Mullard

Published operating points and test conditions from this source.

SECTION 1

Triode

Application

  • Application

    UHF/VHF oscillator or amplifier

Other

  • Plate voltage

    250 V

  • Plate current

    10 mA

  • Transconductance

    8.5 mA/V

  • Amplification factor

    100

  • Plate resistance

    12000 ohm

  • Equivalent noise resistance

    400 ohm

  • Maximum operating frequency

    250 MHz

Data set 04

1963 Philips Electron Tubes Handbook V1a

Published operating points and test conditions from this source.

SECTION 1

Triode

Other

  • Plate voltage

    250 V

  • Grid voltage

    -1.5 V

  • Plate current

    10 mA

  • Maximum plate voltage

    250 V

  • Maximum plate dissipation

    2.5 W

  • Maximum useful frequency

    250 MHz

Characteristic

  • Transconductance

    8500 uS

  • Amplification factor

    100

Capacitance

  • Grid capacitance

    8.5 pF

  • Plate capacitance

    - to 0.2 pF

  • Grid-plate capacitance

    2.5 pF

Data set 05

1999 Philips E-Z

Published operating points and test conditions from this source.

SECTION 1

Triode

Other

  • Typical anode voltage

    250 V

Characteristic

  • Anode-grid capacitance

    0.2 pF

    Maximum