Data set 01
1951 Mullard Valve and Service Manual
Published operating points and test conditions from this source.
Triode
Characteristic
Heater Voltage
6.3 V
Heater Current
650 mA
Other
Plate Supply Voltage
250 V
RCAmplifier
Voltage - Triode (single) ·Triode
Low-impedance triode for voltage amplification or low-power output service; available source data do not establish the project’s 5-watt threshold.
Low-impedance triode for voltage-amplifier or low-power output service.
General specifications
Properties common to every published source and operating point.
Electrical assignments shared by every tube using this base designation.
No verified pinout is recorded for this base designation.
1 physical section, each with unique specifications.
Section 1
Published Mullard ratings and characteristics promoted from the supplied source. Mullard EC31 low-impedance triode, used for voltage amplification or low-power Class A output. Maximum anode voltage 250 V, dissipation 5 W, cathode current 30 mA. Typical Class A output at Va 250 V and Vg -16 V: Ia 20 mA, gm 3.2 mA/V, amplification factor 10.5, plate resistance 3.3 kΩ.
Source-dependent data
Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.
Data set 01
Published operating points and test conditions from this source.
Heater Voltage
6.3 V
Heater Current
650 mA
Plate Supply Voltage
250 V
RCAmplifier