Data set 01
1955 Lorenz
Published operating points and test conditions from this source.
Triode
Construction
Ruggedized construction
TRUE
Application
Maximum intended frequency
800 MHz
Voltage - Triode (single high frequency) ·Triode
Special-quality UHF triode for professional high-frequency service, co-designated with EC806S.
Special-quality UHF triode for professional high-frequency service; equivalent to E86C. This is the E86C co-designation of EC806S.
Small-button Noval 9-contact
General specifications
Properties common to every published source and operating point.
Electrical assignments shared by every tube using this base designation.
No verified pinout is recorded for this base designation.
1 physical section, each with unique specifications.
Section 1
Published Telefunken ratings and characteristics promoted from the supplied source.
Source-dependent data
Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.
Data set 01
Published operating points and test conditions from this source.
Ruggedized construction
TRUE
Maximum intended frequency
800 MHz
Data set 02
Published operating points and test conditions from this source.
Heater Voltage
6.3 V
Heater Current
300 mA
EquivalentDesignation
EC806S
Application
UHF amplifier
Data set 03
Published operating points and test conditions from this source.
Frequency limit
800 MHz
Amplifier service
Noise figure
2 dB
700MHz
Cathode resistance
250 Ohm
Data set 04
Published operating points and test conditions from this source.
oscillating mixer (max. frequency
800 MHz
Published datasheet value
Lite
10000 h
Published datasheet value
Heater voltage V¢
6.3 V
Published datasheet value
Heater current I¢
165 mA
Published datasheet value
Anode current I,
12 mA
Published datasheet value
Mutual conductance S
14 mA/V
Published datasheet value
Heater current It
175 mA
Published datasheet value
Cathode resistor Ry
800 Q
Published datasheet value
Mutual conductance S
9.5 mA/V
Published datasheet value
Anode current I; =
0.1 mA
Published datasheet value
Equivalent noise resistance Req
250 Q
Published datasheet value
Frequency =
100 MHz
Published datasheet value
cathode and heater Ikt max
10 µA
Published datasheet value
and heater Vif =
100 V
Published datasheet value
anode and other electrodes Rins min
100 MQ
Published datasheet value
other clectrode =
300 V
Published datasheet value
other clectrode =
100 V
Published datasheet value
Grid to cathode Cgk
5.6 pF
Published datasheet value
Anode current I, =
12 mA
Published datasheet value
The tube is subjected during
32 h
Published datasheet value
during
10000 h
Published datasheet value
Heater voltage: The average heater voltage should be
6.3 V
Published datasheet value
heater voltage exceeding the range of
6.6 V
Published datasheet value
Anode voltage Vao max
440 V
Published datasheet value
Va max
250 V
Published datasheet value
Anode dissipation W, max
2.4 W
Published datasheet value
Grid voltage —Vg max.,
50 V
Published datasheet value
Grid dissipation Wg max,
20 mW
Published datasheet value
Grid resistor Rg max.,
1.2 MQ
Published datasheet value
Cathode current Ik max
20 mA
Published datasheet value
Voltage between cathode and heater Vit max.,
100 V
Published datasheet value
Frequency (as amplifier) f up to
800 MHz
Published datasheet value
Anode supply voltage Vha
175 V
Published datasheet value
Cathode resistor Rk
125 Q
Published datasheet value
Anode current Iy
12 mA
Published datasheet value
Anode supply voltage Vba
220 V
Published datasheet value
Grid current Ig
50 mA
Published datasheet value