Data set 01
1960 Mazda
Published operating points and test conditions from this source.
Tetrode
Other
Maximum grid 1 voltage
5 V
Minimum negative grid 2 voltage
2 V
Voltage Pentode or Tetrode (under 100V) ·Tetrode-Tetrode
Directly heated dual space-charge-grid electrometer tetrode designed for measuring extremely small currents and voltages, with exceptionally low grid reverse current.
Directly heated dual space-charge-grid electrometer tetrode for measuring extremely small currents and voltages.
Small-button Noval 9-contact
General specifications
Properties common to every published source and operating point.
Electrical assignments shared by every tube using this base designation.
No verified pinout is recorded for this base designation.
2 physical sections, each with unique specifications.
Section 1
Representative section for repeated identical sections.
Section 2
Second physical space-charge-grid electrometer tetrode restored.
Source-dependent data
Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.
Data set 01
Published operating points and test conditions from this source.
Maximum grid 1 voltage
5 V
Minimum negative grid 2 voltage
2 V
Data set 02
Published operating points and test conditions from this source.
GridReverseCurrentMaximum
0.00000000001 mA
Application
Electrometer text