Data set 01
1963 Philips Electron Tubes Handbook V4
Published operating points and test conditions from this source.
Rectifier
Other
Peak inverse voltage
21 kV
Condition1
Peak inverse voltage
15 kV
Condition2
Peak inverse voltage
10 kV
Condition3
Maximum average current
2.5 A
Maximum peak current
10 A
Maximum surge current
100 A
Characteristic
Arc voltage drop
12 V