Skip to main content

Specialized - Thyratron ·Thyratron

DCG66000

Mercury-vapor grid-controlled thyratron for industrial controlled rectification and power-control switching.

Directly heatedCold cathodeCommon cathodeDissimilarSpecialized
Sections
1
Base
-
Socket code
-
Base pins
-
Nominal heater
5 V / 6.5 A

Description

DCG66000 is a Thyratron device in the supplied Philips industrial literature. Grid-controlled mercury-vapour rectifying tube for industrial controlled-rectifier service.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
-
Nominal heater voltage
5 V
Nominal heater current
6.5 A
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Thyratron

X-ray radiationInterelectrode capacitances
Rectifier peak inverse voltage
13000 V
Rectifier peak forward current
40 A
Rectifier forward voltage drop
12 V
Rectifier warm-up time
60 s

Grid-controlled mercury-vapour rectifying tube for industrial controlled-rectifier service.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

1963 Philips Electron Tubes Handbook V4

Published operating points and test conditions from this source.

SECTION 1

Thyratron

Capacitance

  • Grid-to-anode capacitance

    5 pF

Characteristic

  • Arc voltage drop at 1A

    12 V

  • Ionization time

    10 us

  • Deionization time

    250 us

Other

  • Peak inverse anode voltage

    13 kV

  • Peak forward anode voltage

    13 kV

  • Average anode current

    1 A

  • Peak anode current

    4 A

  • Surge current

    40 A

  • Maximum negative grid voltage

    300 V

  • Average grid current

    10 mA

  • Peak grid current

    50 mA

Data set 02

1999 Philips 0-D

Published operating points and test conditions from this source.

SECTION 1

Thyratron

Construction

  • Filling

    Mercury vapour

Characteristics

  • Anode arc voltage at 1 A

    12 V

  • Ionization time

    10 us

  • Deionization time

    250 us

Other

  • Maximum peak inverse anode voltage

    13 kV

  • Maximum peak forward anode voltage

    13 kV

  • Maximum surge current

    40 A

    Duration<=0.1s

  • Maximum grid voltage

    300 V

  • Maximum grid current

    10 mA

  • Maximum peak grid current

    50 mA