Data set 01
1963 Philips Electron Tubes Handbook V4
Published operating points and test conditions from this source.
Rectifier
Other
Peak inverse voltage
15 kV
HighVoltageCondition
Maximum average current
3 A
HighVoltageCondition
Maximum peak current
12 A
HighVoltageCondition
Maximum surge current
120 A
HighVoltageCondition
Peak inverse voltage alternate
2.5 kV
HighCurrentCondition
Maximum average current alternate
5 A
HighCurrentCondition
Maximum peak current alternate
20 A
HighCurrentCondition
Maximum surge current alternate
200 A
HighCurrentCondition
Characteristic
Arc voltage drop
12 V