Data set 01
1999 Philips 0-D
Published operating points and test conditions from this source.
Rectifier
Construction
Filling
Mercury vapour
Other
Maximum RMS anode voltage
8400 V
CircuitDependent
Maximum peak inverse voltage
12000 V
Maximum average anode current
10 A
Maximum peak anode current
50 A
Auxiliary-anode voltage
75-200 V
DC output voltage
3800 V
PublishedCircuit;RMSAnodeVoltage=4200V
DC output current
20 A
PublishedCircuit;RMSAnodeVoltage=4200V
Output power
76 kW
PublishedCircuit;RMSAnodeVoltage=4200V
DC output voltage
5800 V
PublishedCircuit;RMSAnodeVoltage=4900V
DC output current
30 A
PublishedCircuit;RMSAnodeVoltage=4900V
Output power
174 kW
PublishedCircuit;RMSAnodeVoltage=4900V
DC output voltage
5400 V
PublishedCircuit;RMSAnodeVoltage=4200V
DC output current
40 A
PublishedCircuit;RMSAnodeVoltage=4200V
Output power
216 kW
PublishedCircuit;RMSAnodeVoltage=4200V
DC output voltage
7600 V
PublishedCircuit;RMSAnodeVoltage=8400V
DC output current
20 A
PublishedCircuit;RMSAnodeVoltage=8400V
Output power
152 kW
PublishedCircuit;RMSAnodeVoltage=8400V
DC output voltage
11600 V
PublishedCircuit;RMSAnodeVoltage=8400V
DC output current
30 A
PublishedCircuit;RMSAnodeVoltage=8400V
Output power
348 kW
PublishedCircuit;RMSAnodeVoltage=8400V
DC output voltage
10800 V
PublishedCircuit;RMSAnodeVoltage=8400V
DC output current
40 A
PublishedCircuit;RMSAnodeVoltage=8400V
Output power
432 kW
PublishedCircuit;RMSAnodeVoltage=8400V
Characteristics
Forward voltage drop
16 V