Data set 01
1963 Philips Electron Tubes Handbook V4
Published operating points and test conditions from this source.
Rectifier
Capacitance
Anode capacitance
4 pF
Grid capacitance
13 pF
Characteristic
Deionization time
- to 500 us
Maximum
Ionization time
- to 10 us
Maximum
Arc voltage drop at 2.5A
12 V
Other
Peak inverse anode voltage
27 kV
Peak forward anode voltage
27 kV
Average anode current
2.5 A
Peak anode current
10 A
Surge current
100 A
Duration<=0.1s
Maximum negative grid voltage
300 V
BeforeConduction
Average grid current
25 mA
Peak grid current
125 mA