Data set 01
1963 Mullard
Published operating points and test conditions from this source.
Triode
Other
Anode voltage
20 V
Va=20 V
Anode current
0.5 mA
Va=20 V
Grid voltage
-1 V
Va=20 V
Anode voltage
40 V
Va=40 V
Anode current
1.8 mA
Va=40 V
Grid voltage
-2.8 V
Va=40 V
Plate voltage maximum
100 V
Grid circuit resistance maximum
1 Mohm
Characteristic
Transconductance
350 uS
Va=20 V
Plate resistance
13500 ohm
Va=20 V
Amplification factor
4.7
Va=20 V
Transconductance
620 uS
Va=40 V
Plate resistance
7600 ohm
Va=40 V
Amplification factor
4.7
Va=40 V