Data set 01
1946 Standard Telephone and Cables
Published operating points and test conditions from this source.
Thyratron
Other
Heater voltage
6.3 v
Nominal curren
600 mA
Cathode heating time, minimum
10 sec
Grid to anode
0.026 pF
Inpu
2.4 pF
Outpu
1.6 pF
conduction
-100 v
before conduction
-100 v
Maximum peak cathode curren
500 mA
Maximum average cathode curren
100 mA
Maximum fault curren
10 A
Maximum duration of fault curren
0.1 sec
Maximum average screen curren
10 mA
Maximum average control grid curren
10 mA
cathode
25 v
Anode voltage (r.m.s.) 117
400 v
Direct screen grid voltage 0
0 v
Direct control grid voltage —
-6 A
Peak control grid signal voltage 5
3 v
~ 2021 AVERAGE GRID CHARACTERISTICS |Vh=
6.3 V
< BEFORE ANODE CONOUCTION. Ve
0 V
E B
300 V
Y_0-02
400 V
2D 2 AVERAGE GRID CHARACTERISTICS|Vh=
6.3 V
HIT Vh
63 V
life for heater voltage range of 5.7 to
6.9 Volts
Characteristic
Deionization . {v 125M\735u\;Ed
100 v
me, approx Rg; 1000 0
10.1 A
Va 125V1 Vg, —
10 V
Rg11000Q I
100 mA
Critical grid With V,
460 V
current, max. la av
100 mA
Voltage drop, approx
8 v