Data set 01
1955 Marconi
Published operating points and test conditions from this source.
Voltage Regulator
Other
VOLTAGE STABILISER QS8 [1]
3 V
VOLTAGE STABILISER QS83/3
VOLTAGE STABILISER QS8 [2]
3 V
VOLTAGE STABILISER QS83/3
HIGH STABILITY - SINGLE GAP APRIL,
1955
HIGH STABILITY - SINGLE GAP APRIL, 1955
Stabilityt< (Any subsequent [1]
100
Stabilityt< (Any subsequent 100 hrs.) + 0-1 %
Stabilityt< (Any subsequent [2]
0
Stabilityt< (Any subsequent 100 hrs.) + 0-1 %
Stabilityt< (Any subsequent [3]
-1
Stabilityt< (Any subsequent 100 hrs.) + 0-1 %
* Half arithmetic sum of change in voltage [1]
2 V
* Half arithmetic sum of change in voltage 2---3 mA 4-change in voltage 3—4 mA.
* Half arithmetic sum of change in voltage [2]
-3 V
* Half arithmetic sum of change in voltage 2---3 mA 4-change in voltage 3—4 mA.
* Half arithmetic sum of change in voltage [3]
4 V
* Half arithmetic sum of change in voltage 2---3 mA 4-change in voltage 3—4 mA.
* Half arithmetic sum of change in voltage [4]
3 V
* Half arithmetic sum of change in voltage 2---3 mA 4-change in voltage 3—4 mA.
* Half arithmetic sum of change in voltage [5]
-4 V
* Half arithmetic sum of change in voltage 2---3 mA 4-change in voltage 3—4 mA.
t Maximum variation of voltage at constant current (preferably
3 V
t Maximum variation of voltage at constant current (preferably 3 mA).
In order to obtain maximum stability (less than [1]
0 V
In order to obtain maximum stability (less than 0-1%, change in voltage over long
In order to obtain maximum stability (less than [2]
-1 V
In order to obtain maximum stability (less than 0-1%, change in voltage over long
connecting a suitable stabiliser in cascade with the QS8 [1]
3
connecting a suitable stabiliser in cascade with the QS83/3.
connecting a suitable stabiliser in cascade with the QS8 [2]
3
connecting a suitable stabiliser in cascade with the QS83/3.
The circuits shown in Figs [1]
2 V
The circuits shown in Figs. 2 and 3 are recommended when a very stable voltage
The circuits shown in Figs [2]
3 V
The circuits shown in Figs. 2 and 3 are recommended when a very stable voltage
of approximately
83 mA
of approximately 83V is required ; the load should draw a constant current, which may
zero to
3 V
zero to 3 mA, and the permissible changes in input voltage V| are also given, together
If a different voltage, or a current greater than
3 V
If a different voltage, or a current greater than 3mA is required, it is necessary
using a QS8 [1]
3 V
using a QS83/3 as the voltage reference source for the network.
using a QS8 [2]
3 V
using a QS83/3 as the voltage reference source for the network.
Stabilized voltage
83 V
Published regulated voltage.
Tube current minimum
1 mA
Minimum maintaining current.
Tube current maximum
5 mA
Maximum operating current.
Ignition voltage
125 V
Published minimum or maximum ignition/start voltage as applicable.