Data set 01
1958 Compagnie General
Published operating points and test conditions from this source.
Microwave
Characteristic
CenterFrequency
300 GHz
RelativeOscillationBandwidthMinimum
7 %
RelativeOscillationBandwidthMaximum
10 %
AverageCWPower
5 mW
Specialized - Microwave Tube ·Microwave
Water-cooled millimeter-wave Carcinotron backward-wave oscillator electronically tunable around 285–305 GHz with permanent-magnet focusing and milliwatt-level output.
Water-cooled carcinotron backward-wave oscillator centered near 300 GHz with electronic tuning.
General specifications
Properties common to every published source and operating point.
Electrical assignments shared by every tube using this base designation.
No verified pinout is recorded for this base designation.
1 physical section, each with unique specifications.
Section 1
Backward-wave oscillator electron-stream section; line/Wehnelt values have no direct fixed promoted fields.
Source-dependent data
Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.
Data set 01
Published operating points and test conditions from this source.
CenterFrequency
300 GHz
RelativeOscillationBandwidthMinimum
7 %
RelativeOscillationBandwidthMaximum
10 %
AverageCWPower
5 mW
Data set 02
Published operating points and test conditions from this source.
Frequency range minimum
285 GHz
Frequency range maximum
305 GHz
Heater current minimum
1.8 A
Heater current maximum
2.4 A
Minimum RF output power
10 mW
Frequency=285-305GHz
Peak-point RF output power minimum
60 mW
Frequency=290-310GHz;AtLeastOnePoint
Warm-up time minimum
4 min
Maximum heater surge current
25 A
Maximum anode voltage
3000 V
Maximum anode current
10 mA
Maximum line voltage
7000 V
Maximum line current
80 mA
Maximum Wehnelt current
5 mA
Typical line current
60 mA
Typical heater voltage
-7.5 V
Typical heater current
2.1 A
Typical Wehnelt voltage
-50 V