Data set 01
1958 Compagnie General
Published operating points and test conditions from this source.
Microwave
Characteristic
OperatingFrequencyMinimum
1200 MHz
OperatingFrequencyMaximum
1500 MHz
PowerOutputMinimum
500 W
Specialized - Microwave Tube ·Microwave
Integral-magnet Carcinotron crossed-field backward-wave oscillator electronically tunable from approximately 1.2–1.5 GHz and delivering at least 500 W output.
Carcinotron backward-wave oscillator with integral magnet, electronically tunable over 1200–1500 MHz and rated above 500 W.
General specifications
Properties common to every published source and operating point.
Electrical assignments shared by every tube using this base designation.
No verified pinout is recorded for this base designation.
1 physical section, each with unique specifications.
Section 1
No fixed ratings are recorded for this section.
Published ratings and characteristics promoted from the supplied CSF/Thomson source where explicitly available.
Source-dependent data
Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.
Data set 01
Published operating points and test conditions from this source.
OperatingFrequencyMinimum
1200 MHz
OperatingFrequencyMaximum
1500 MHz
PowerOutputMinimum
500 W