Skip to main content

Nixie ·Nixie

CK6476

Gas-filled cold-cathode 4 kHz bidirectional ring-stepping decade counter with visual or electrical readout of the active count position.

Directly heatedCold cathodeCommon cathodeDissimilar
Sections
1
Base
-
Socket code
-
Base pins
13
Nominal heater
-

Description

Gas-filled cold-cathode 4 kHz bidirectional ring-stepping decade counter with visual or electrical readout. The datasheet specifies anode/supply limits, counting frequency, and a typical resistor-biased operating point.

General specifications

Tube and section characteristics

Properties common to every published source and operating point.

Heater and base

Base
-
Socket code
-
Base pins
13
Nominal heater voltage
-
Nominal heater current
-
Parallel heater voltage
-
Parallel heater current
-
Series capable
No

Terminal pinout

Electrical assignments shared by every tube using this base designation.

No verified pinout is recorded for this base designation.

Section ratings

1 physical section, each with unique specifications.

Section 1

Nixie

X-ray radiationInterelectrode capacitances
Max cathode current
0.5 mA

Cold-cathode gas-discharge decade-counter section; conventional gm/rp/mu fields are not applicable.

Source-dependent data

Operating conditions by source

Each block preserves the test conditions and published values from one reference. Values from different sources are intentionally kept separate.

Data set 01

196X Nixie Random Datasheets

Published operating points and test conditions from this source.

SECTION 1

Nixie

Other

  • Total anode current maximum

    0.5 mA

  • Voltage between electrodes maximum

    140 V

    Excluding anode

  • Supply voltage minimum

    350 V

    Anode-to-cathode

  • Input frequency maximum

    5000 pps

  • DC supply voltage

    425 V

  • Anode resistor

    0.82 MΩ

  • Cathode resistor

    100000 Ω

Characteristics

  • Nominal tube drop

    195 V

    Typical operation

  • Output voltage

    30 V

    Across cathode resistor

  • Minimum guide pulse width

    10 µs

    Typical driver operation